Monitors network interfaces and shows current traffic in a textbox.
mynet = lain.widgets.net()
input table
Variable | Meaning | Type | Default |
---|---|---|---|
timeout |
Refresh timeout seconds | int | 2 |
iface |
Network device | string | autodetected |
units |
Units | int | 1024 (kilobytes) |
notify |
Display "no carrier" notifications | string | "on" |
screen |
Notifications screen | int | 1 |
settings |
User settings | function | empty function |
Possible other values for units
are 1 (byte) or multiple of 1024: 1024^2 (mb), 1024^3 (gb), and so on.
If notify = "off"
is set, the widget won't display a notification when there's no carrier.
settings
can use the following iface
related strings:
net_now.carrier
("0", "1");net_now.state
("up", "down");net_now.sent
andnet_now.received
(numbers).
output
A textbox.
Notes
If the widget spawns a "no carrier" notification and you are sure to have an active network device, then autodetection is probably not working. In this case you can set iface
manually. You can see which device is UP with the following command:
ip link show